The waveform display shows the waveform image of the edited audio clip.

This should not be confused with the 'Full Height' and 'Half Height' options, which change the size of the entire display, rather than the size of the graph on the display. The scaling buttons. A portion of a waveform, scaled up. The same waveform, scaled down. Changing the Display Type. When creating a waveform image, specifies the start time, in seconds.-end, -e (default: 0) When creating a waveform image, specifies the end time, in seconds. Note: this option cannot be used if the -zoom option is specified.-width, -w (default: 800) When creating a. Tektronix ASI Option for WFM2300 Portable Waveform Monitor (Pre-Installed) B&H # TEWFM2300ASI MFR # WFM2300 ASI. See All Details. Available in other Styles, Configurations & Kits. Promo Financing. Add to Cart. Add to Wish List. Under the options menu, a Custom waveform can be created and file imported as pattern or play data. For the Noise signal, the Frequency represents the DAC update rate, and the Symmetry and Phase parameters are disabled. The Sine-Power signal is a sine signal where the power attribute is 0. Which options are available here depends on the codec selected at the Wave format option (e.g. Some codecs only support 4 bit resolution). If you were to choose Microsoft PCM Converter as the codec, and 44,100 Hz, 16 Bit, Stereo as the output format, it would be the same as doing an uncompressed CD rip.

Waveform Options
  1. Level Scale

    Indicates the amplitude of the audio.

  2. Level Scale options

    Allow you to select whether the level is shown as percentage or in dB.

  3. Ruler

    Shows the project tempo grid.

  4. Audio waveform

    Shows the waveform image of the selected audio.

  5. Half Level Axis

    To show the half level axis, open the audio waveform context menu and select Show Half Level Axis.

Elliott Wave Options

Note

Elliott Wave Options Rob Roy

To set up a wave image style open the Preferences dialog and select Event Display > Audio.

Options Permanent Wave Option 2

Keyword

Data Type

Default Value

Description

abstol

Num.

1pA

Absolute current error tolerance

baudrate

Num.

(none)

Used for eye diagrams. Tells the waveform viewer how to wrap the abscissa time to overlay the bit transitions.

chgtol

Num.

10fC

Absolute charge tolerance

cshunt

Num.

0.

Optional capacitance added from every node to ground

cshuntintern

Num.

cshunt

Optional capacitance added from every device internal node to ground.

defad

Num.

0.

Default MOS drain diffusion area

defas

Num.

0.

Default MOS source diffusion area

defl

Num.

100µm

Default MOS channel length

defw

Num.

100µm

Default MOS channel width

delay

Num.

0.

Used for eye diagrams. Shifts the bit transitions in the diagram.

fastaccess

flag

false

Convert to fastaccess file format at end of simulation.

flagloads

flag

false

Flags external current sources as loads.

Gmin

Num.

1e-12

Conductance added to every PN junction to aid convergence.

gminsteps

Num.

25

Set to zero to prevent gminstepping for the initial DC solution.

gshunt

Num.

0.

Optional conductance added from every node to ground.

itl1

Num.

100

DC iteration count limit.

FNaF World's gameplay is the one typically found in the JRPG genre. In other words, you manage a group of characters, level them up, equip them with different objects, etc. The battles, just like how they used to be in JRPGs from the 90s, are random and annoying; and they're turn-based. FNaF World is an entertaining but improvable JRPG. Fnaf 2 for free download. Fnaf 1 download media fire. Fnaf 2 download MEGA. Fnaf 2 download media fire. Powered by Create your own unique website with customizable templates. Sister location downloads fnaf 1 and 2 downloads fnaf 3 and 4 downloads Fnaf comedy fnaf world Movies Fan games.

itl2

Num.

50

DC transfer curve iteration count limit.

itl4

Num.

10

Transient analysis time point iteration count limit

itl6

Num.

25

Set to zero to prevent source stepping for the initial DC solution.

srcsteps

Num.

25

Alternative name for itl6.

maxclocks

Num.

Infin.

maximum number of clock cycles to save

maxstep

Num.

Infin.

Maximum step size for transient analysis

meascplxfmt

string

bode

Complex number format of .meas statement results. One of 'polar', 'cartesian', or 'bode'.

measdgt

Num.

6

Number of significant figures used for .measure statement output.

method

string

trap

Numerical integration method, either trapezoidal or Gear

minclocks

Num.

10

minimum number of clock cycles to save

MinDeltaGmin

Num.

1e-4

Sets a limit for termination of adaptive gmin stepping.

nomarch

flag

false

Do not plot marching waveforms

noopiter

flag

false

Go directly to gmin stepping.

numdgt

Num.

6

Historically 'numdgt' was used to set the number of significant figures used for output data. In LTspice, if 'numdgt' is set to be > 6, double precision is used for dependent variable data.

pivrel

Num.

1e-3

Relative ratio between the largest column entry and an acceptable pivot value.

pivtol

Num.

1e-13

Absolute minimum value for a matrix entry to be accepted as a pivot.

reltol

Num.

.001

Relative error tolerance.

srcstepmethod

Num.

0

Which source stepping algorithm to start with.

sstol

Num.

.001

Relative error for steady-state detection.

startclocks

Num.

5

Number of clock cycles to wait before looking for steady state.

temp

Num.

27ºC

Default temperature for circuit element instances that don't specify temperature.

tnom

Num.

27ºC

Default temperature at which device parameters were measured for models that don't specify this temperature.

topologycheck

Num.

1

Set to zero to skip check for floating nodes, loops of voltage sources, and non-physical transformer winding topology

trtol

Num.

1.0

Set the transient error tolerance. This parameter is an estimate of the factor by which the actual truncation error is overestimated.

trytocompact

Num.

1

When non-zero, the simulator tries to condense LTRA transmission lines' history of input voltages and currents.

vntol

Num.

1µV

Sets the absolute voltage error tolerance.

plotreltol

Num.

.0025

Sets the relative error tolerance for waveform compression.

plotvntol

Num.

10µV

Sets the absolute voltage error tolerance for waveform compression.

plotabstol

Num.

1nA

Sets the absolute current error tolerance for waveform compression.

plotwinsize

Num.

300

Number of data points to compress in one window. Set to zero to disable compression.

ptrantau

Num.

.1

Characteristic source start-up time for a damped pseudo transient analysis to find the operating point. Set to zero to disable pseudo transient.

ptranmax

Num.

0

If set non-zero, that time of the damped pseudo transient analysis is used as the operating point whether the circuit has settled or not.

Coments are closed